簡(jiǎn)要描述:西門子數(shù)控系統(tǒng)報(bào)警207900代碼解決維修,西門子S120報(bào)警7410維修,S120驅(qū)動(dòng)器接地報(bào)警維修,S120控制器過載故障維修,西門子雙軸電機(jī)模塊通訊壞31885報(bào)警維修,西門子整流單元維修,變頻器報(bào)F30001過流維修,西門子S120驅(qū)動(dòng)器控制板故障維修,過載F30005報(bào)警,接地F30021故障,主軸電機(jī)驅(qū)動(dòng)器啟動(dòng)報(bào)7802維修,驅(qū)動(dòng)器沒準(zhǔn)備就緒,缺少軸使能報(bào)警,
更新時(shí)間:2024-03-21
產(chǎn)品型號(hào):
廠商性質(zhì):工程商
西門子數(shù)控系統(tǒng)報(bào)警207900代碼解決維修,西門子S120報(bào)警7410維修,S120驅(qū)動(dòng)器接地報(bào)警維修,S120控制器過載故障維修,西門子雙軸電機(jī)模塊通訊壞31885報(bào)警維修,西門子整流單元維修,變頻器報(bào)F30001過流維修,西門子S120驅(qū)動(dòng)器控制板故障維修,過載F30005報(bào)警,接地F30021故障,主軸電機(jī)驅(qū)動(dòng)器啟動(dòng)報(bào)7802維修,驅(qū)動(dòng)器沒準(zhǔn)備就緒,缺少軸使能報(bào)警,西門子S120電源模塊報(bào)警230052維修,201951故障,S120電源230002故障,直流母線過壓報(bào)警,西門子電壓模塊300602故障,840D電源模塊過載維修,230005維修,S120電源接地報(bào)警,230021功率部件接地,S120整流單元F31885故障,S120欠壓故障230003,西門子S120電源相位故障報(bào)警,201303驅(qū)動(dòng)部件不支持要求,S120電源ALM跳閘維修,西門子S120模塊BLM無輸出維修,西門子數(shù)控系統(tǒng)報(bào)警207900代碼解決維修
232131 <地點(diǎn)信息>編碼器 2:增量/絕對(duì)位置差過大
驅(qū)動(dòng)對(duì)象: HLA_828, SERVO_828, SERVO_COMBI
信息值: %1
反應(yīng): Servo: OFF1 (IASC/DCBRK, OFF2, OFF3, STOP2, 無)
Hla: OFF1 (OFF2, OFF3, STOP2, 無)
應(yīng)答: 封S脈沖
原因: 絕對(duì)值編碼器:
在循環(huán)讀取絕對(duì)位置時(shí),發(fā)現(xiàn)絕對(duì)位置和增量位置相差太大。讀出的絕對(duì)位置被拒。
偏差的極限值:
- EnDat 編碼器:由編碼器提供,并且至少有 2 個(gè)象限(比如 EQI1325>2 個(gè)象限,EQN1325>50 個(gè)象限)。
- 其它編碼器:15 條線 = 60 個(gè)象限。
增量編碼器:
越過零脈沖時(shí),發(fā)現(xiàn)和增量位置有偏差。
等距零脈沖:
- 第一個(gè)越過的零脈沖為所有下面的檢查確定參考點(diǎn)。之后的零脈沖相對(duì)于第一個(gè)零脈沖成 n 倍距。
等距零脈沖:
- 第一對(duì)零脈沖為所有下面的檢查確定參考點(diǎn)。之后的零脈沖對(duì)之間的距離必須與第一對(duì)零脈沖間的期望距離一致。
故障值(r0949,十進(jìn)制):
以象限表示的偏差(1 條線=4 個(gè)象限)。
排除方法: - 檢查編碼器電纜的布線是否符合 EMC 準(zhǔn)則。- 檢測(cè)插塞連接。
- 更換編碼器或者編碼器電纜。
- 檢查碼盤污染情況或者周圍的強(qiáng)磁場(chǎng)。
- 修改零脈沖距離的參數(shù)(p0425)。
- 出現(xiàn)超過轉(zhuǎn)速閾值信息時(shí),必要時(shí)降低濾波時(shí)間 (p0438)。